Stryker Duracon Total Knee

Stryker Duracon Total Knee



Duracon Trial Cutting Guide Tibial Preparation Prepare the tibia following the Duracon Total Stabilizer Revision Knee System Surgical Protocol (Lit. No. LTSST, pages 8-11). If an offset is needed, use the tibial offset reamer to prepare for the tibial offset. Insert the assembled trial into the tibia (Figure 1 and Figure 2). Note: The Duracon …


Knee . Implants. We offer market-leading knee replacement implants for partial knee and total knee arthroplasty for primary and revision procedures featuring our cemented and cementless flagship TKA solution, the Triathlon Knee System.


Triathlon – Stryker MedEd, Triathlon – Stryker MedEd, Total Knee Replacement Implants | Stryker, Total Knee Replacement Implants | Stryker, Stryker/Howmedica Duracon Total Knee System Tibial Trial Inserts Standard Tibial Insert Trials Catalog # Description 6631-1-109 Small, 9 mm 6631-1-111 Small, 11 mm 6631-1-113 Small, 13 mm 6631-1-116 Small, 16 mm 6631-1-119 Small, 19 mm 6631-1.


Duracon Total Knee System,The Duracon tibial inserts have radiused A/P and M/L dishes produced by advanced 4-axis machining, maximizing conformity of the tibial insert to the radiused condyles of the femoral component. The resulting rotary arc is unique to the Duracon system, and accommodates the knee ‘s natural screw-home m,medicine,medical supply,medical supplies,medical product, Stryker/Howmedica Duracon Total Knee System Tibial Trial Inserts Stryker/Howmedica Duracon Total Knee System Tibial Insert Trials and Instrumentation Join Our Email List Visit Medical Products Resource. A-Z Ortho 917 Lone Oak Rd Suite 1000 Eagan, MN 55121 Info@m-p-r.com Call 800.524.5194, Stryker -Initiated Dynamic Computer Simulations of Passive ROM and Oxford Rig Test, Stephen Piazza, 2003. Wang H, Simpson KJ, Ferrara MS, Chamnongkich S, Kinsey T, Mahoney OM. Biomechanical differences exhibited during sit-to-stand between total knee arthroplasty designs of varying radii. J Arthroplasty. 200621(8):1193-1199.


5/5/2006  · Stryker Howmedica Osteonics Corp. 325 Corporate Dr Mahwah NJ 07430: For Additional Information Contact: Rita Intorella 201-831-5000 Manufacturer Reason for Recall: A box packaged and labeled as a Duracon Total Knee Duration A-P Lipped Tibial Insert 11MM may actually contain a 9MM insert. FDA Determined Cause 2: Labeling mix-ups: Action, During total knee replacement (which is also called total knee arthroplasty), your surgeon removes the damaged surfaces of the knee joint and replaces them with metal and plastic components referred to as the prosthesis or implant. The implant is designed to replace the function of a healthy knee .


With over 10 years and over 2 million implantations worldwide, Triathlon has a long clinical history. 1-3 In a recent 10 year follow up study Triathlon showed 99% survivorship. 3 Triathlon was designed to incorporate some of the most studied features of Stryker ’s prior designs that have been shown to address many of the main reasons for revision TKA such as instability, patellofemoral …


Stryker ’s Triathlon is a total knee system that has over a decade of proven performance in both Australia and New Zealand, recording one of the highest published survivorship rates of all knee prostheses in the market at 96.6% 27 and 97.4% 22 respectively after ten years.. Stryker ’s knee philosophy is focused around ‘Soft Tissue Guided Motion’ where the implant respects the soft tissue …

Advertiser